NO: E-29021|61686|2023|Electrical(HQ) Dhanbad, Date: 27/10/2023
DGMS APPROVAL NO.-663 of 2013
From
Director General of Mines Safety
Directorate General of Mines Safety,
P.O & Distt: Dhanbad - 826 016.
To
SONGIT KUMAR BAGRODIA, CUPRUM BAGRODIA LTD., 23C ASHUTOSH CHOWDHURY AV, KCI PLAZA, KOLKATA
West Bengal, KOLKATA, KOLKATA, 700019
Sub: Approval under Regulation 208 (3) of the Coal Mines Regulations, 2017 Flameproof and Intrinsically safe electrical items (as mentioned in Annexure-I) associated with Bucyrus Highwall Miner Serial no. SHM 69 manufactured by M/s. Caterpillar Global Mining LLC, USA for use in belowground Coal Mines in India in the name of the user M/s. Cuprum Bagrodia Ltd., Kolkata – Renewal thereof.
Sir,
Please refer to your online application No. E-29021|61686|2023|Electrical(HQ) dated 26.09.2023 and the previously approved application no. E-29021/30621/2020/Electrical (HQ) dated 21.09.2020 on the above subject and Test Reports as reffered to in Annexure-I and other documents submitted therewith in this regard.
I, in exercise of powers conferred upon Chief Inspector of Mines (also designated as Director General of Mines Safety) under Regulation 208(3) of the Coal Mines Regulations, 2017, hereby renew the approval (DGMS Approval No. 663 of 2013) granted vide this Directorate's letter No. 530/1179/EHQ dated 25.06.2013 for a further period of two years, i.e. up to 26.10.2025 for use in belowground Coal Mines. The conditions mentioned in the original approval and subsequent renewal letters shall be strictly complied with.
Please note that application for renewal should be made at least three (03) months before the date of expiry of the approval.
Enclosure: Annexure – I.
|
Your Sincerely, |
 |
(PRABHAT KUMAR)
Director General of Mine Safety - (HQ)
Date : 27.10.2023
Annexure-I
List of flameproof and intrinsically safe electrical equipment incorporated/associated Bucyrus Highwall Miner manufactured by M/s. Caterpillar Global Mining Highwall Miners LLC, USA for use in belowground Coal Mines.
Sl. No.
|
Description of FLP electrical equipments
|
Manufacturer
|
Test report
|
IS/IEC standard
|
1.
|
FLP high voltage junction box, 1100V, 600A, model no. FLP-AMCPL-HVB-01
|
M/s. Sait Teknik Pvt. Ltd.
(M/s Advamind Consulting Private Limited)
|
IN/CIMFR/TR23/R/H120 dated 05.07.2023
|
IS/IEC 60079-0:2014
IS/IEC 60079-1:2017
|
2.
|
FLP low voltage control box, model no. FLP-AMCPL-LVB-01, rated 24 VDC, 10 A.
|
M/s Sait Teknik Pvt. Ltd.
(M/s Advamind Consulting Private Limited)
|
IN/CIMFR/TR23/R/H120 dated 05.07.2023
|
IS/IEC 60079-0:2014
IS/IEC 60079-1:2017
|
3.
|
FLP Navigation box, model no.FLP-AMCPL-NB-01, rated 24 VDC, 10 A.
|
M/s Sait Teknik Pvt. Ltd.
(M/s Advamind Consulting Private Limited)
|
IN/CIMFR/TR23/R/H120 dated 05.07.2023
|
IS/IEC 60079-0:2014
IS/IEC 60079-1:2017
|
4.
|
Flameproof induction motor, model no. P36G9602 rated 165 HP, 6 pole, 995 V, 50 Hz, 1180 RPM, water cooled. C.I.
|
M/s Baldor Reliance
|
IN/CIMFR/TR22/C/H358 dated 24.11.2022
|
IS/IEC 60079-0:2014
IS/IEC 60079-1:2017
|
5.
|
FLP/IS power supply, model TX6620/6630 Series (12 Vdc) rated Um:250 VAC, Ui:230 VAC, Vo:14.4 VDC, Io:2.37 A
|
M/s Trolex Limited
|
IECEx TSA 09.0006X dated 02.05.2022
|
IEC 60079-0:2014
IEC 60079-11:2011
|
6.
|
Trip Amplifier, model no. TX9131 rated input supply Ui=16.5 VDC, input signal (sensor)=4 to 20 mA
|
M/s Trolex Limited
|
ERTL(E)/TES/T238/0004/01-22/NABL dated 21.02.2022
|
IS/IEC 60079-0:2014
IS/IEC 60079-11:2011
|
7.
|
Flameproof Gas Sensor (CH4), model no. STX3261.01.11.240 rated input supply (max) Ui=14.4 VDC, signal output=0.4 VDC to 2 VDC
|
M/s Trolex Limited
|
ERTL(E)/TES/T238/0003/01-22/NABL dated 21.02.2022
|
IS/IEC 60079-0:2014
IS/IEC 60079-11:2011
|
8.
|
FLP hydraulic valve twin Solenoid assembly, model-01 EX05 053C YzYz, rated at 24 V, 1.33 A, M.S.
|
M/s Schienale Magnettchnik+Elektronik GmbH
|
IN/CIMFR/TR22/C/H359
dated 24.11.2022
|
IS/IEC 60079-0:2014
IS/IEC 60079-1:2017
|
|
Your Sincerely,
|
 |
(PRABHAT KUMAR)
Director General of Mine Safety - (HQ)
Date : 27.10.2023
|