Sl. No.
|
Description of electrical equipment
|
Manufacturer
|
Testing Laboratory
|
Test Report No. & Date
|
Standard to which the test is conducted
|
|
1
|
FLP 3 Phase, induction motorratedat 37KW,550/1100V,4pole,1500 RPM,320T, Pump Motor
|
Baldor(ABB)
|
SIRA Certification Services, UK
|
IECEx SIR 09.0011X
2023-02-14
|
IEC 60079-0:2017
IEC 60079-1:2014
|
|
2
|
FLP enclosure for cable reel rated at 300A, 1100V
|
JOY
|
SIRA Certification Services, UK
|
IECEx CML 23.0084X
2023-08-01
|
IEC 60079-0:2017
IEC 60079-1:2014
|
|
3
|
Connection Box,5100019785,1100V(Cable reel to controller)
|
JOY
|
TÜV Rheinland Australia Pty. Ltd.
|
IECEx ITA 15.0016
2023-10-18
|
IEC 60079-0:2017;
IEC 60079-1:2014
|
|
4
|
Connection/Switch Box, Type5100002582,240V,50A, EmergencyStop
|
JOY
|
Ex Testing & Certification Pty. Ltd., AUS
|
IECEx ITA 10.0002X
2023-05-30
|
IEC 60079-0:2017
IEC 60079-1:2014
|
|
5
|
Interface Relay TX6661,8.5V/13V, housed inside FLP enclosure Model No. 5100016553
|
Housed Inside FLP enclosure- 5100016553, Sr no 16
|
|
6
|
FLPcontroller station type CT900,rated 1100V,(main controller)
|
EMIS
|
MASC, South Africa
|
IECEx ICS 23.0016U
2023-12-14
|
IEC 60079-0:2017;
IEC 60079-1:2014
|
|
7
|
FLP/WP LED mining Luminary, type ML100, 12-24V AC/DC
(Head/tail lights)
|
Victor
|
Intertek Testing & Certification Ltd, UK
|
IECEx ITS 08.0012
2022-05-10
|
IEC 60079-0:2017
IEC 60079-1:2014
|
|
8
|
Switch Connection Box, 1100V, Model
5000016252,(Key/ Start/ stop switch)
|
JOY
|
Eurofins E&E CML Limited, UK
|
IECEx CML 16.0002
2023-10-31
|
IEC 60079-0:2017;
IEC 60079-1:2014
|
|
9
|
FLP/WP LED mining Luminary, type ML102, 110V, 15 W
|
Victor
|
SIRA Certification Services, UK
|
SIRA09ATEX1328
Sept-2021
|
EN IEC 60079-0:2018
IEC 60079-1:2014
|
|
10
|
Siren Model - HSHC, Alarm
|
Hytronic
|
MASC, South Africa
|
IECEx ICS 17.0003X
2023-10-25
|
IEC 60079-0:2017;
IEC 60079-1:2014;
IEC 60079-11:2023
|
|
11
|
STX-3261 Methane SENSOR
|
Trolex Ltd.
|
ERTL, Kolkata
|
ERTL(E )/TES/T238/0003/01-22/NABL
2022-02-21
|
IEC 60079-0:2017;
IEC 60079-11:2011
|
|
12
|
IS Power supply, BBU TX6648,7.5V/12V
(Battery Back-up Unit)
|
Trolex Ltd.
|
Eurofins E&E CML Limited, UK
|
IECEx CML 21.0048X
2021-07-06
|
IEC 60079-0:2017
IEC 60079-11:2011
|
|
13
|
TX9042 Programmable SensorController
|
Trolex Ltd.
|
SGS Baseefa Limited, UK
|
IECEx BAS 15.0065X
2023-09-07
|
IEC 60079-0:2017
IEC 60079-11:2023
|
|
14
|
Isolating SwitchAmplifier,Type IM1-451-Ex-R,housed inside Main controller CT900
|
Turck
|
TÜV NORD CERT GmbH, Germany
|
IECEx TUN 06.0007X
2022-04-20
|
IEC 60079-0:2017
IEC 60079-11:2011
|
|
15
|
Global range of adaptors and blanking plug
|
JOY
|
Ex Testing & Certification Pty. Ltd., Australia
|
IECx ITA 07.0016U
2019-12-17
|
IEC 60079-0:2017;
IEC 60079-1:2014
|
|
16
|
FLP enclosure for battery Back-unit, Model No. 5100016553,120V
|
JOY
|
CML, UK
|
IECEx CML 18.0112X,
dated 2021-03-17
|
IEC 60079-0:2017;
IEC 60079-11:2014;
IEC 60079-11:2011
|