NO: E-29021|62427|2025|Electrical(HQ) Dhanbad, Date: 03.09.2025
DGMS APPROVAL NO.708 of 2016
From
Director General of Mines Safety
Directorate General of Mines Safety,
P.O & Distt: Dhanbad - 826 016.
To
REINHARD REINARTZ, Sandvik Mining and Construction G.m.b.H, SANDVIK MINING AND CONSTRUCTION G.M.B.H., ALPINESTRASSE 1, 8740 ZELTWEG, AUSTRIA
Steiermark, zeltweg, ZELTWEG, 8740
Subject: Approval under Regulation 208(3) of the Coal Mines Regulations, 2017 for Flameproof and Intrinsically safe electrical apparatus of DGMS approval no. 708 of 2016 (as mentioned in Annexure-B) associated with Sandvik Shuttle Car, Type – TC790, manufactured by M/s. Sandvik Mining and Construction GmbH, Austria, for use in below-ground coal mines in India– Renewal thereof
Sir,
Please refer to your online application No. E-29021|62427|2025|Electrical (HQ) dated 27.06.2025 on the above subject and test reports and other documents submitted therewith in this regard.
I, in exercise of powers conferred upon Chief Inspector of Mines (also designated as Director General of Mines Safety) under Regulation 208(3) of the Coal Mines Regulations, 2017, hereby renew the approval (DGMS Approval No. 708 of 2016) granted vide this Directorate's letter No. 515/1012/EHQ dated 17.05.2016 for a further period of two years, i.e. up to 02.09.2027 for use in belowground Coal Mines. The conditions mentioned in the original approval and subsequent renewal letters, if any, shall be strictly complied with, and the test reports of all the electrical items covered under this approval, conforming to the latest applicable testing standards, shall be submitted within three months, if not submitted before.
Condition: The latest applicable standard, IS/IEC 60079-11:2023, must be submitted to this Directorate within three (03) months from the date of issue of the renewal permission. Failing this, the permission is liable to be withdrawn without further communication
The application for renewal should be made at least three (03) months before the date of expiry of the approval.
|
Your Sincerely, |
 |
(UJJWAL TAH)
Director General of Mine Safety - (HQ)
Date : 03.09.2025 |
THIS IS A SYSTEM GENERATED DOCUMENT, DOES NOT REQUIRE ANY SIGNATURE. |
Annexure-B
Sl.
No.
|
Details of FLP, IS electrical components and cables
|
Manufacturer
|
ERTS/CIMFR/ERDA
Test Report No.
|
QAR/QAN
|
1.
|
Flameproof and weatherproof TRAM MOTOR, in fabricated mild Steel construction as designated by Type NO. dKSV36TM/3-6 rated at 40kW, 3 phase, 1100Volt, 50Hz, 6 Pole, 900-3450 rpm, IP55, conforming to IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
BREUER
MOTOREN,
Germany
|
CIMFR Test Report:
IN/CIMFR/TR23/R/H430,
Dt:12.01.2023
|
DE/BVS/QAR08.0006/14 (valid til 25.02.2027)
|
2.
|
Flameproof and weatherproof CONVEYOR MOTOR, in fabricated mild Steel construction as designated by Type No. dKSV36TM/2-4 rated at 50kW, 3 phase, 1100 Volt, 50Hz,4 Pole, 1440 rpm, IP55, conforming to IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
BREUER
MOTOREN,
Germany
|
CIMFR Test Report:
IN/CIMFR/TR23/R/H431,
Dt:12.01.2023
|
DE/BVS/QAR08.0006/14 (valid til 25.02.2027)
|
3.
|
Flameproof and weatherproof HYDRAULIC MOTOR in fabricated mild Steel construction as designated by Type No dAM160LX4LX rated at 15kW, 3 phase, 1100 Volt, 50Hz, 4 Pole, 1500 rpm, IP55 , conforming to IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
BARTEC,
Germany
|
CIMFR Test Report:
IN/CIMFR/TR23/R/H441, Dt:25.01.2023
|
DE/BVS/QAR21.0006/05 (valid til 28.10.2027)
|
4.
|
Flameproof and weatherproof MAIN PANEL, in fabricated mild Steel construction as designated by Type No. ASC18-MP1 rated at 130A, 3 phase, 1100 Volt, 50 Hz, IP54, conforming to IS/IEC 60079-0:2017 and IS/IEC 60079-1:2014.
|
OSTROZ-
HANSEN & REINDERS
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H473, Dt:23.02.2023
|
CZ/FTZU/QAR10.0001/14 (valid til 30.09.2027)
|
5.
|
Flameproof and weatherproof ROTARY TRANSFORMER (CABLE REEL) in fabricated mild steel construction as designated by Type No BTT200 rated at 100A, 3 Phase, 1140Volt, 50 Hz, 120rpm, IP54, conforming to IS/IEC 60079-0:2004 and IS/IEC 60079-1:2007
|
BARTEC,
Germany
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H492, Dt:14.03.2023
|
DE/BVS/QAR21.0006/05 (valid til 28.10.2027)
|
6
|
Flameproof and weatherproof MASTER CONTROL in fabricated mild Steel construction as designated by Type No ASC18-MC1 rated at 12VDC and 12VAC, 50Hz, IP54, conforming to IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
OSTROZ-
HANSEN & REINDERS
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H480, Dt:03.03.2023
|
CZ/FTZU/QAR10.0001/14 (valid til 30.09.2027)
|
7.
|
Flameproof and weatherproof FOOT SWITCH in fabricated mild Steel construction as designated by Type No ASC18-FS1 rated at 24VDC, 0.03A, IP54, conforming to IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
OSTROZ-
HANSEN & REINDERS
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H452, Dt:09.02.2023
|
CZ/FTZU/QAR10.0001/14 (valid til 30.09.2027)
|
8.
|
Flameproof and weatherproof CONNECTION BOX in fabricated mild Steel construction as designated by Type No ASC18-CB1, rated at 130A, 1100V, 3 Phase, 50 Hz, IP54, conforming to IS/IEC 60079-0:2004 and IS/IEC 60079-1:2007
|
OSTROZ-
HANSEN & REINDERS
|
CIMFR Test Report:
IN/CIMFR/TR23/R/H485,
Dt:09.03.2023
|
CZ/FTZU/QAR10.0001/14 (valid til 30.09.2027)
|
9.
|
Flameproof and weatherproof MAXI LIGHT in fabricated mild Steel construction as designated by Type No S316(R) rated at 30W/50W, conforming to equivalent IS/IEC 60079-0:2017 and IS/IEC 60079-1:2014
|
HYTRONIC,
SOUTH AFRICA
|
MASC IA Certificate no:
MASC MS/21-2420X, Dt:04.02. 2022,
for
SANS (IEC) 60079-0: 2019
SANS (IEC) 60079-1: 2015
|
ZA/ICS/QAR14.0003/08 (valid til 21-02-2027)
|
10.
|
Flameproof and weatherproof MINI LIGHT in fabricated mild Steel construction as designated by Type No S312 rated at 30/35/50W, conforming to equivalent IS/IEC 60079-0:2017 and IS/IEC 60079-1:2014
|
HYTRONIC,
SOUTH AFRICA
|
MASC IA Certificate no:
MASC MS/21-2420X, Dt:04.02. 2022,
for
SANS (IEC) 60079-0: 2019
SANS (IEC) 60079-1: 2015
|
ZA/ICS/QAR14.0003/08 (valid til 21-02-2027)
|
11.
|
Flameproof and weatherproof SIREN in fabricated mild Steel construction as designated by Type No HSHC, conforming to equivalent IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60079-11:2011.
|
HYTRONIC,
SOUTH AFRICA
|
MASC IA Certificate no:
MASC MS/10-279X, 05.04.2022
for
SANS (IEC) 60079-0: 2019
SANS (IEC) 60079-1: 2015
SANS 60079-11: 2012
|
ZA/ICS/QAR14.0003/08 (valid til 21-02-2027)
|
12.
|
Flameproof and weatherproof ROTATING LIGHT BEACON in fabricated mild Steel construction as designated by Type No HFRL conforming to equivalent IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60079-11:2011.
|
HYTRONIC,
SOUTH AFRICA
|
MASC IA Certificate no:
MASC MS/14-0407X,
21.04.2022
for
SANS (IEC) 60079-0: 2019
SANS (IEC) 60079-1: 2015
SANS 60079-11: 2012
|
ZA/ICS/QAR14.0003/08 (valid til 21-02-2027)
|
13
|
Flameproof and weatherproof EMERGENCY STOP STATION in fabricated mild Steel construction as designated by Type No HMHES rated at up to 220V AC. IP54, conforming to IS/IEC 60079-0:2017, IS/IEC 60079-1:2014, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
HYTRONIC,
SOUTH AFRICA
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H475, Dt:27.02.2023
|
ZA/ICS/QAR14.0003/08 (valid til 21-02-2027)
|
14.
|
Intrinsically Safe POWER SUPPLY designated by Type No. iNTA43A rated I/p-42/230V AC at 50Hz, O/p- 12VDC, 1.5A conforming to equivalent IS/IEC 60079-0:2017, IS/IEC 60079-11:2011, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
TIFENBACH
GmbH.
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H491,Dt:14.03.2023
|
PL_OBAC_QAR20.0001/04 (valid til 30.05.2026)
|
15.
|
Intrinsically Safe weatherproof SOLENOID designated by Type No. iEA33A/1RSL Ui=13.5VDC, Ii=260/13mA, IP54 conforming to IS/IEC 60079-0:2017, IS/IEC 60079-11:2011, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
TIFENBACH
GmbH
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H456, Dt:16.02.2023
|
PL_OBAC_QAR20.0001/04 (valid til 30.05.2026)
|
16.
|
Intrinsically Safe REAL BARRIER designated by Type No. EP01 P8 rated Ui=13.2VDC, Un=12 Ii=50mA, conforming to IS/IEC 60079-0:2017, IS/IEC 60079-11:2011, and IS/IEC 60529-2001(Reaffirmed as 2014)
|
OSTROZ-
HANSEN & REINDERS
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H456, Dt:16.02.2023
|
CZ/FTZU/QAR10.0001/14 (valid til 30.09.2027)
|
17.
|
Hydraulic Pump Motor rated at 15KW 1100v 4KTCR 160 L-4
|
M/s Bartec Varnost
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H436, Dt:18.01.2023
|
SI/SIQ/QAR11.0003/09 (Valid till 25.05.2026)
|
18.
|
Area Light rated at 110V 15W ML 102
|
M/s Victor UK
|
CIMFR Test Report.
IN/CIMFR/TR23/R/H472, Dt:23.02.2023
|
GB/SIR/QAR06.0055/08 (Valid till 17.11.2026)
|
|