emblem
  • भारत सरकार
  • GOVT. OF INDIA
  • श्रम एवं रोजगार मंत्रालय
  • MINISTRY OF LABOUR AND EMPLOYMENT
  • खान सुरक्षा महानिदेशालय
  • DIRECTORATE GENERAL OF MINES SAFETY

Application

Approval Letter View

Approved No :- 62218 dated 28.04.2025

NO: E-29021|62218|2025|Electrical(HQ)

Dhanbad, Dated:28.04.2025

DGMS APPROVAL NO.66 of 1993(Renewal)

From

Director General of Mines Safety
Directorate General of Mines Safety,
P.O & Distt: Dhanbad - 826 016.

To

DEEPAK JAIN SANGHVI, Simplex Engineering & Foundry Works Pvt. Ltd., 65 INDUSTRIAL ESTATE, BHILAI , DIST - DURG
Chhattisgarh, DURG, BHILAI, 490026

Subject: Approval under Regulation 208(3) of the Coal Mines Regulations, 2017 for Flameproof and Intrinsically safe electrical equipment associated with Crawler Mounted Low Profile electro-hydraulic Side Discharge Loader (SDL) with cable reeling drum model : D-113/1000 (as mentioned in Annexure-B of Approval No.66 of 1993) manufactured by M/S Simplex Engineering & Foundry Works Pvt. Ltd., Bhilai490 026 (Chhatisgarh) for use in belowground Coal Mines in India– Renewal thereof.

Sir,

Please refer to your online application No. E-29021/62218/2025/Electrical (HQ) dated 03.02.2025 on the above subject and test reports and other documents submitted therewith in this regard.

I, in exercise of powers conferred upon Chief Inspector of Mines (also designated as Director General of Mines Safety) under Regulation 208(3) of the Coal Mines Regulations, 2017, hereby renew the approval (Approval No. 66 of 1993) granted vide this Directorate's letter No. 443/847/EHQ dated 05.06.1993 for a further period of two years, i.e. up to 24.03.2027 for use in belowground Coal Mines in India. 

In the interest of safety, the OEM guidelines shall be adhered to and spares, supplied by OEM shall only be used while maintaining the apparatus. The conditions mentioned in the original approval and subsequent renewal letters, if any, shall be strictly complied with and the test reports of all the electrical apparatus covered under approval, conforming to the latest testing standards, shall be submitted within three months, if not submitted before.

Please note that application for renewal should be made at least three (03) months before the date of expiry of the approval.

Your Sincerely,
(UJJWAL TAH)
Director General of Mine Safety - (HQ)
Date : 30.04.2025

Annexure-A

List of FLP/WP apparatus associated with the Crawler Mounted Low Profile electro-hydraulic Side Discharge Loader (SDL) with cable reeling drum model : D-113/1000 manufactured by M/S Simplex Engineering & Foundry Works Pvt. Ltd., Bhilai-490026 (Chhatisgarh) of the DGMS approval no.66 of 1993

Sl.No. Details of FLP Electrical Components Name of the Manufacturer Testing Agency Test Certificate.  Standard to which the test was conducted.
1 MOTOR         
1

Motor, 3 Phase Fas cooled mountd FLP squirrel cage induction motor  fmame size E-250M, rated at 55KW/75HP, 440/550 Voltls, Synchoroous speed continues duty in class 'F' insulation manufactured by M/s CG Power and Industrial Solution Ltd.

OR

3 Phase Fan Cooled mounted FLP squirrel cage induction,motor frame size LE-250M, rated at 55KW/75HP, 440/550 Volts, 50 Hz, Synchronous speed continues duty in class 'F' insulation, manufactured by M/s Laxmi Hydralics Pvt. Ltd.

M/s CG Power and Industrial Solution Ltd. 

 

 

M/s Laxmi Hydralics Pvt. Ltd.

M/s ERTL, Kolkata

 

 

M/s ERTL, Kolkata

ERTL(E)/TES/C299/0020/08-22/NABL dated 27.09.2022

 

ERTL(E)/TES/L077/0026/11-22/NABL dated 09.03.2023

IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  

 

IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  

2 Flameproof Plug & Socket, Type A & Type B M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR  IN/CIMFR/TR19/13 dated 07.01.2020 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022 IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
3 FLOAT/LEVEL SWITCH M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H 2663 dated 05/11/2019 0 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
4 FLP/WP Emergency Stop Push Button Station, Type KPBI-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H166 dated 01.10.2019 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
5 FLP/WP HEAD LIGHT, Type KHL-A&B M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H191 dated 20.11.2019 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
6 FLP JUNCTION BOX, Type KPBI-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H166 dated 01.10.2019 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
7 LIGHTING TRANSFORMER, KLTI-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H175 dated 06.11.2019  & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022 IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
8 FLP CABLE REELING DRUM WITH PLUG & SOCKET, Type KRD-1 M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H168 dated 17/10/2019 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022 IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
9 FLP Foot Switch Assebly Type KLS-A. M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR  IN/CIMFR/TR19/H189 dated 07.01.2020 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022 IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
10 TEMPERATRURE SWITCH, Type KSWI-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H 2663 dated 05/11/2019 0 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
11 FLP Control Station with Starat Stop Bush Button, Type KPBI-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H168 dated 01.10.2019 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
12 LIMIT SWITCH, Type KLS-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR  IN/CIMFR/TR19/H189 dated 07.01.2020 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022 IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
13 FLP Rotary Switch Type KPB2-A M/s Kaysons Techno Equipment Pvt Ltd, Gujrat M/s CIMFR IN/CIMFR/TR19/H166 dated 01.10.2019 & CIMFR/FES/Clarification/22-23/249 dated 15th July, 2022. IS/IEC 60079-1:2017  & IS/IEC 60079-1:2014  
Your Sincerely,
(UJJWAL TAH)
Director General of Mine Safety - (HQ)
Date : 30.04.2025
THIS IS A SYSTEM GENERATED DOCUMENT, DOES NOT REQUIRE ANY SIGNATURE.
Back