Approved No :- 62033 dated 06.11.2024

NO: E-29021|62033|2024|Electrical(HQ)                                                                                                                                                                                                                                   Dhanbad, Date: 06.11.2024

DGMS Approval No. 843 of 2024

From

Director General of Mines Safety
Directorate General of Mines Safety,
P.O & Distt: Dhanbad - 826 016.

To

KEVIN REYNDERS, Rham Equipment, 7 AXLE ROAD, CLAYVILLE, EXT 1, OLIFANTSFONTEIN, 1665
Gauteng, CLAYVILLE, JOHANNESBURG, 65980

Subject: Approval under Regulation 208(3) of the Coal Mines Regulations, 2017 for Flameproof and Intrinsically safe electrical apparatus as listed in the enclosed Annexure-A incorporated/associated with the Roof Bolter, Model: TB2035, manufactured by M/s. Rham Equipment Pty. Ltd., South Africa conforming to IS/IEC:60079-0:2017, IS/IEC:60079-1:2014 and IS/IEC:60079-11:2011 for use in belowground coal mines in India- Regular approval thereof.

Sir,

I, in exercise of powers conferred upon Chief Inspector of Mines (also designated as Director General of Mines Safety) under Regulation 208(3) of the Coal Mines Regulations, 2017 and in reference to Field Trial approval issued vide letter No. E-29021|61513|2023|Electrical(HQ) dated 03.05.2023, the test reports as listed in annexure B and based on the performance report received from the Gayatri Underground Coal Mine of M/s. South Eastern Coalfield Limited hereby accord the approval (DGMS Approval No. 843 of 2024) for a period of five years from the date of issue of this letter, i.e. up to 06.11.2024 for use in belowground coal mines in India with the conditions as mentioned in the enclosed  Annexure-A.

Please note that application for renewal should be made at least three (03) months before the date of expiryof the approval.

Yours Sincerely,
(UJJWAL TAH)
Director General of Mine Safety - (HQ)
Date: 06.11.2024

Annexure-A

Conditions for approval under Regulation 208(3) of the Coal Mines Regulations, 2017 for flameproof and Intrinsically safe electrical apparatus as listed in the enclosed Annexure-A incorporated/associated with the Roof Bolter, Model: TB2035, manufactured by M/s. Rham Equipment Pty. Ltd., South Africa conforming to IS/IEC:60079-0:2017, IS/IEC:60079-1:2014 and IS/IEC:60079-11:2011 for use in belowground Coal mines in India.

  1. Every unit shall carry conspicuously in a permanent manner the aforesaid identification mark, i.e.‘DGMS Approval No. 843 of 2024’.
  2. In addition, every unit shall also carry permanently this Directorate’s approval mark, as below:

 

  1. The design of the electrical circuit shall not be changed without obtaining prior approval from this director.
  2. Conspicuous warning inscriptions against opening the cover of the main enclosure or of any apparatus which gives access to the flameproof enclosures on live parts, or which is designed to receive cable attachment unless the supply to the unit is isolated at the source, shall be affixed permanently on the respective part to ensure that all live parts within the unit are made dead and safe.
  3. Spare parts shall be made readily available to the user as and when required for proper maintenance of the equipment.
  4. The customer shall be supplied a copy of this approval letter, the test report from the testing laboratory with the lab-certified drawing, an extract of the condition & special conditions, maintenance schedule, if any, recommended by the testing laboratory in their test report(s) so as to maintain safety features of apparatus/equipment.
  5. The customer shall also be provided a copy of the factory test report along with drawings, instruction manual on the installation, operation and maintenance of the equipment and spare parts catalogue at the time of delivery of the equipment.
  6. The user shall furnish the performance report of the equipment directly to this Directorate after one(01) year of actual use.
  7. While seeking renewal, valid BIS license in the case of Indian manufacturers and in the case of foreign manufacturers, QAR/QAN, as may be applicable shall be submitted and the same shall remain valid as long as the apparatus is manufactured and marketed.
  8. Any modification to the equipment that might be considered necessary at a later date shall be effected upon being so directed by this Directorate.
  9. The cables connecting with Equipment shall conform to the provisions of the DGMS Tech. Circular(Electrical) No. 12 dated 25.05.2015 and corrigendum vide DGMS Tech. Circular (Electrical)Approval No. 01 dated 19.02.2016 in addition to the special requirement, if any, specifically for safe operation of the equipment.
  10. All covers doors/access covers of the electrical equipment mounted on the equipment, on opening/removal which may explosive internal conductors, shall have warning instructions either by raised lettering or by other suitable means against such opening/removal of covers, doors, and access covers, without isolating supply of energy to the equipment from its source.
  11. The plug and socket assembly affixed to the motors/panel if provided, will be so interlocked as to prevent removal of plug from the socket while alive.
  12. In the interest of safety, the OEM guidelines shall be adhered to and spares, supplied by OEM shall only be used while maintaining the apparatus. Spare parts shall be made readily available as and when required for proper maintenance of the equipment. Any failure in the equipment shall be intimated to this Directorate.
  13. All sensing devices shall be regularly tested and, routinely calibrated or verified to ensure correct operation and a record of the same shall be maintained.
  14. The associated items for which approval has been issued are exclusively for use as part of this equipment only and shall not be read as individual approval for those items.
  15. The electrical equipment and cables associated with the machine shall be checked by the ElectricalSupervisor of the mine for their respective flameproofness of the equipment and condition of cables at the beginning of each working shift and the findings thereof enter a bound-paged book maintained for that purpose which shall be duly signed by the Electrical Supervisor with the date.
  16. Test reports as per the latest applicable standards for the Methane Monitoring System(ultimaX), MSA Co. USA make(Listed at sln.14 of Annexure-B) shall be submitted within three months from the date of issue of this approval. To ensure compliance, the test certificate/report should be uploaded to this portal, referencing the approval ID 62033. Additionally, in the event of any revision of standards applicable to the product/equipment, the manufacturer shall get the product/equipment tested as per revised standards and submit test reports to the customer for information and to this Directorate for further approval/renewal.
  17. The cable entry devices, threaded adaptors and stopping plugs shall be suitable for the equipment and be considered as a part of the equipment (not a component). The cable entry device and cabling methods used shall be suitable for their intended duty and for the special type of cable used in mining. Such cable entry devices shall be duly certified as per relevant IS/IEC standards.
  18. The approval of the subject equipment is with regard to Ex-standards. Other relevant standards applicable for assessment of its electrical parameters required under type test have not been taken into consideration.
  19. All circulars/general approvals issued by DGMS from time to time, relevant to the equipment shall also be complied with.
  20. The relevant provisions of the Central Electricity Authority (Measures relating to Safety and ElectricSupply) Regulations,2023 shall be complied with in all matters relating to the installation, operation, and maintenance of the equipment.
  21. The approval is accorded for a period of five years i.e. up to 06.11.2029.
  22. At the time of applying for renewal, details of supply with the name of mines, purchase order and date shall be furnished with the application.
  23. If at any time any of the conditions subject to which this approval has been granted, is violated, or not complied with, this approval shall be deemed to have been revoked with immediate effect.
  24. The above approval may be amended or withdrawn at any time, if considered so necessary in the interest of safety and is being issued without prejudice to any other provisions of law which may be or may become applicable at any time.
Yours Sincerely,
(UJJWAL TAH)
Director General of Mine Safety - (HQ)
Date: 06.11.2024

Annexure-B

List of electrical equipment for Flameproof and Intrinsically safe electrical apparatus as listed in the enclosed Annexure-A incorporated/associated with the Roof Bolter, Model: TB2035, manufactured by M/s. Rham Equipment Pty. Ltd., South Africa conforming to IS/IEC:60079-0:2017, IS/IEC:60079-1:2014 and IS/IEC:60079-11:2011 for use in belowground coal mines in India under Regulation 208(3) of the Coal Mines Regulations, 2017.

SL NO

DESCRIPTION
(Type/Model number/Frame size)

NAME OF THE MANUFACTURER

Testing Laboratory

TEST CERTIFICATE(COC) NUMBER

STANDARD OF THE CONDUCTED TEST

1

Motor, 55KW, 50Hz, 4-pole, 1440 rpm Top box foot mounted

WEG EQUIPMENT ELETRICOS S/A, BRAZIL

TUV Rheinland Industrie Service GmbHAm

Grauen Stein 51105 Cologne Germany

Christian MehrhoffAssigned certifier

 

IECEx TUR 18.0066X Dated 30.11.2022

IEC 60079-0:2017

IEC 60079-1:2014-06

2

Flashing Light/Resin
timer Type- FL1, Voltage-12V, Wattage- 25W, LED

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/17-2569 X Dated 29.04.2022

IEC 60079-0:2019

IEC 60079-1:2015

3

FLUORESCENT LIGHT Type - HDFL2 Voltage-12V, 30W

HYTRONICS (Pty)LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC MS/13-839X Dated 13.10.2022

IEC 60079-0:2019

IEC 60079-1:2015

4

DRIVE LIGHT type- HLT-1, 12V, 50W, LED Cluster

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/17-2568X Dated 29.04.2022

IEC 60079-0:2019

IEC 60079-1:2015

5

START STOP STATION, 10 Amps

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/15-1813 Dated 29.04.2022

IEC 60079-0:2019

IEC 60079-1:2015

6

Emergency Stop

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/15-1811 Dated 29.04.2022

IEC 60079-0:2019

IEC 60079-1:2015

7

SIREN Type-HSHC, 

HYTRONICS (Pty)LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC MS/22-2347X Dated 04.11.2022

IEC 60079-0: 2019

IEC 60079-1:2015

IEC 60079-11:2012

8

Electric Panel Enclosure- FE7 Voltage-1000 V, Amp- 140A

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/17-2570X Dated 04.11.2022

IEC 60079-0:2019

IEC 60079-1:2015

9

CONNECTION BOX (FE1)

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/19-0535U Dated 03.05.2022

IEC 60079-0:2019

IEC 60079-1:2015

10

PRESSURE SWITCH Type-OPS/DM1 Voltage-12V

HYTRONICS (Pty)LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC MS/12-068X Dated 14.03.2022

IEC 60079-0:2019

IEC 60079-1:2015

11

PLUG SOCKET 1100 Volt, 250 Amps

VICTOR PRODUCTS LTD, UK

Mining and Surface Certification(Pty) Ltd, South Africa

MASC MS/18-1198X Dated 25.05.2018

IEC 60079-0:2019

IEC 60079-1:2015

12

LS4 Float Level Switch

HYTRONICS (Pty)LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC MS/17-0018X Dated 13.10.2022

IEC 60079-0:2019

IEC 60079-1:2015

13

PROXIMITY SWITCH

RHAM EQUIPMENT (PTY) LTD, SA

Mining and Surface Certification(Pty) Ltd, South Africa

MASC M/20-2404X Dated 02.12.2020

IEC 60079-0: 2019

IEC 60079-18:2016

14

Methane Monitoring System (UltimaX)

MSA Co. USA

-

DGMS Approval No 3081 of 2009

IEC 60079-0: 2019

IEC 60079-1:2014-06

Yours Sincerely,