Approved No :- E-29021|61872|2024|Electrical(HQ)  dated 26.06.2024

NO: E-29021|61872|2024|Electrical(HQ)                                                                                                           Dhanbad, Date: 26.06.2024            

                                                                                        DGMS APPROVAL NO.- 834 of 2024

From

Director General of Mines Safety
Directorate General of Mines Safety,
P.O & Distt: Dhanbad - 826 016.

To

REINHARD REINARTZ, Sandvik Mining and Construction G.m.b.H, SANDVIK MINING AND CONSTRUCTION G.M.B.H., ALPINESTRASSE 1, 8740 ZELTWEG, AUSTRIA
Steiermark, ZELTWEG, ZELTWEG, 8740

Subject:- Approval under  Regulation 208(3) of the Coal Mines Regulations, 2017 for Flameproof and Intrinsically Safe electrical apparatus  (as mentioned in Annexure – B) associated with the Methane Monitoring system manufactured by M/s Nautitech Australia to be used in Diesel Utility Vehicle Model LS190 in belowground coal mines in India under Regulation 208(3) of the Coal Mines Regulations, 2017 - Regular approval thereof.

Sir,

I, in exercise of powers conferred upon Chief Inspector of Mines (also designated as Director General of Mines Safety) under Regulation 208(3) of the Coal Mines Regulations, 2017 and in reference to Field Trial approval No. 532/EHQ dated 21.06.2019, DGMS Approval no. MECH-142410/2022/03 dated 24.01.2022, Test Report as per annexure ‘B’ and based on the performance reports received from the Adriyala Longwall project, APA, of M/s. The Singareni Collieries Company Limited and the Director of Mines Safety (Electrical), South Central Zone, DGMS, Hyderabad, hereby accord the approval (DGMS Approval No. 834 of 2024)  for a period of two years, i.e. up to 26.06.2026 for use in belowground coal Mines with the condition as mentioned in Annexure-A.

Please note that application for renewal should be made at least three (03) months before the date of expiry of the approval.

Your Sincerely,

(PRABHAT KUMAR)
Director General of Mine Safety - (HQ)
Date : 26.06.2024

Enclosure: Annexure – A&B.

Annexure-A

Conditions for Approval under Regulation 208(3) of the Coal Mines Regulations, 2017 for Flameproof and Intrinsically Safe electrical apparatus  (as mentioned in Annexure – B) associated with the Methane Monitoring system manufactured by M/s Nautitech Australia to be used in Diesel Utility Vehicle Model LS190 in belowground coal mines in India under Regulation 208(3) of the Coal Mines Regulations, 2017

  1. Every unit shall carry conspicuously in a permanent manner the aforesaid identification mark, i.e. ‘DGMS Approval No. 834 of 2024’.
  1. In addition, every unit shall also carry permanently this Directorate’s approval mark, as below:

                                                                      

  1. (a) The design of the electrical circuit shall not be changed without obtaining prior approval from this Directorate.

            (b) Conspicuous warning inscriptions against opening the cover of the main enclosure or of any apparatus which gives access to the flameproof enclosures on live parts, or which is designed to receive cable attachment unless the supply to the unit is isolated at source, shall be affixed permanently              on the respective part to ensure that all live parts within the unit are made dead and safe.

  1. Spare parts shall be made readily available to the user as and when required for proper maintenance of the equipment.
    1. The customer shall be supplied the copy of this approval letter, the test report from the testing laboratory with the lab certified drawing, an extract of the condition & special conditions, maintenance schedule, if any, recommended by the testing laboratory in their test report(s) so as to maintain safety features of apparatus/equipment.
    2. The customer shall also be provided a copy of factory test report along with drawings, instruction manual on the installation, operation and maintenance of the equipment and spares parts catalogue at the time of delivery of the equipment.
  2. The user shall furnish the performance report of the equipment directly to this Directorate after one (01) year of actual use.
  1. While seeking renewal, valid BIS license in the case of Indian manufacturers and in case of foreign manufacturers, QAR/QAN, as may be applicable shall be submitted and the same shall remain valid as long as the apparatus is manufactured and marketed.
  1. Any modification to the equipment that might be considered necessary at a later date shall be effected upon being so directed by this Directorate.
  1. The high pressure hydraulic hoses supplied with the machine shall conformed to the standards and parameters as prescribed in the DGMS/Mech/Tech.Cir (Approval) No. 04, Dhanabd, dated 13.02.2015
  1. The Fire Resistant Hydraulic Fluid supplied with the machine shall conform to the standards and parameters as prescribed in DGMS/Mech/Tech.Cir (Approval) No. 02, Dhanbad, dated 13.02.2015.
  1. The cables connecting with Equipment shall conform to the provisions of the DGMS Tech. Circular (Electrical) No. 12 dated 25.05.2015 and corrigendum vide DGMS Tech. Circular (Electrical) Approval No. 01 dated 19.02.2016 in addition to the special requirement, if any, specifically for safe operation of the equipment.
  1. All covers, doors/access covers of the electrical equipment mounted on the equipment, on opening/removal which may expose live internal conductors, shall have warning instructions either by raised lettering or by other suitable means against such opening/removal of covers, doors and access covers, without isolating supply of energy to the equipment from its source.
  1. The plug and socket assembly affixed to the motors/panel, if provided, will be so interlocked as to prevent removal of plug from the socket while alive.
  1. In the interest of safety, the OEM guidelines shall be adhered to and spares, supplied by OEM shall only be used while maintaining the apparatus. Spare parts for replacement shall be made readily available as and when required for proper maintenance of the equipment. Any failure in the equipment shall be intimated to this Directorate.
  1. All sensing devices shall be regularly tested and, routinely calibrated or verified to ensure correct operation and a record of the same shall be maintained.
  1. The associated items for which approval has been issued is exclusively for use as part of this equipment only and shall not be read as individual approval for those items.
  1. The electrical equipment and cables associated with the machine shall be checked by the Electrical Supervisor of the mine for their respective flame proofness of the equipment and condition of cables in the beginning of each working shift and the findings thereof enter into a bound-paged book maintained for that purpose which shall be duly signed by the Electrical Supervisor with the date.
  1. If there occurs any revision of standards applicable to the product/equipment, the manufacturer shall get the product/equipment tested as per revised standards and submit test reports to the customer for information and to this Directorate for further approval/renewal.
  1. The cable entry devices, threaded adaptors and stopping plugs shall be suitable for the equipment and be considered as a part of equipment (not a component). The cable entry device and cabling methods used shall be suitable for their intended duty and for the special type of cable used in mining. Such cable entry devices shall be duly certified as per relevant IS/IEC standards.
  1. The approval of the subject equipment is with regard to Ex standards mentioned herein. Other relevant standards applicable for assessment of its electrical parameters required under type test have not been taken into consideration.
  1. All circulars/general approvals issued by DGMS from time to time, relevant to the equipment shall also be complied with.
  1. The relevant provisions of the Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2010 shall be complied with in all matter relating to the installation, operation and maintenance of the equipment.
  1. The approval is accorded for a period of two years i.e. till 26.06.2026.
  1. At the time of applying for renewal, details of supply with name of mines, purchase order and date shall be furnished with the application.
  1. If at any time any of the conditions subject to which this approval has been granted, is violated or not complied with, this approval shall be deemed to have been revoked with immediate effect.
  1. The above approval may be amended or withdrawn at any time, if considered so necessary in the interest of safety and is being issued without prejudice to any other provisions of law which may be or may become applicable at any time.
  1. You shall submit the test reports conforming the latest applicable testing standards within three months if not submitted before.
  1. You shall submit the complete single line diagram of all the supply lines and the electrical apparatus incorporated with the Diesel Utility Vehicle, Model: LS 190 along with the control and safety features provided within three months’ time.
Your Sincerely,

(PRABHAT KUMAR)
Director General of Mine Safety - (HQ)
Date : 26.06.2024

Annexure-B

List of Flameproof and Intrinsically Safe electrical apparatus associated with the Methane Monitoring system manufactured by M/s Nautitech Australia to be used in Diesel Utility Vehicle Model LS190 in belowground coal mines in India under Regulation 208(3) of the Coal Mines Regulations, 2017.

Sl .No

Description with

Type/Model No., Frame Size etc.,

Name of the Manufacturer

Name of the testing laboratory

Standard of test

Test certificate/report number & (Associated Drawing no.)

1

Flameproof enclosure 5410 series, MES410-2-99-333 which houses isolation switch, Pressure switch, Solenoid valve, Battery pack and associated equipment.

(Methane Monitoring system)

 

Nautitech, Australia

                  CIMFR, Dhanbad

 

                                &

 

Ex Testing and Certification Pty Ltd, Australia.

IS/IEC 60079-0:2017

IS/IEC 60079-1:2014

IN/CIMFR/TR23/R/H217 Dated 07.09.2023

(Total 09 drawings as detailed in para 13 (Page 2 of 5) of the above test report.)

2)Other associated test reports.

i)IN/CIMFR/TR23/R/H310 dated 15.12.2023,

ii)IN/CIMFR/TR23/R/H218 dated 07.09.2023,

iii)IN/CIMFR/TR24/R/H381 dated 19.03.2024,

iv)IECEx ITA 14.0009X dated 20.08.2021,  

2

Flameproof Alternator, 500W, 12V/24VDC, Type 001215/MOD 15/4X

MAE Manufacturers CC, South Africa

South Africa Mining and surface certification(MASC), Gauteng, SA

IEC 60079-0:2017

IEC 60079-1:2014

IECEx ICS 15.0004X dated 03.02.2023

(As mentioned in para 5 (page 31 of 32) of the test report:.MASC report no.13-124R1 dated 16.03.2016)

Your Sincerely,

(PRABHAT KUMAR)
Director General of Mine Safety - (HQ)
Date : 26.06.2024

THIS IS A SYSTEM GENERATED DOCUMENT, DOES NOT REQUIRE ANY SIGNATURE.