Please refer to your online application No. E-29021|62699|2026|Electrical (HQ), dated 14/01/2026, on the above subject, and the test reports and other documents submitted therewith in this regard.
I, in exercise of powers conferred upon the Chief Inspector of Mines (also designated as Director General of Mines Safety) under Regulation208(3) of the Coal Mines Regulations, 2017, hereby renew the approval (DGMS Approval No. 829 of 2024) granted vide this Directorate’s letter No. E-29021|61813|2024|Electrical(HQ), Dhanbad, Date: 24.04.2024 for a further period of two years, i.e., up to 05.03.2028 for use in belowground Coal Mines. The conditions mentioned in the original approval, subsequent renewal letters, and the amendment approval (wherever applicable), issued vide letter no. E-29021|61813|2024|Electrical(HQ), Dhanbad, Date: 24.04.2024, shall be strictly complied with, and the test reports of all the electrical items covered under approval, conforming to the latest testing standards, shall be submitted within three months, if not submitted before. The OEM guidelines shall be adhered to, and spares supplied by OEM shall only be used while maintaining the machines in the interest of safety.
The application for renewal should be made at least three (03) months before the date of expiry of this approval.
Condition: The latest test report conforming to the IS/IEC 60079-11:2023 may please be submitted to this Directorate within three (03) months from the date of issuance of this approval. In case the same is not received within the stipulated period, the approval may be reviewed, which could lead to its withdrawal.
Annexure-A
List for Flameproof and Intrinsically safe electrical apparatus as listed in the appended Annexure-B associated with Roof bolter, Model: HDDR, manufactured by M/s. J.H. Fletcher & Co., for use in below-ground coal mines in India under Regulation 208(3) of the Coal Mines Regulations,
|
S.N.
|
Description of the equipment
|
Manufacturer
|
Testing Laboratory
|
Test Certificate No. & Date
|
Standards by which the test is conducted
|
|
1
|
FLP 3 Phase, induction motor rated at 37KW, 550/1140V, 4 pole, 1500 RPM, Pump Motor
|
Baldor (ABB)
|
SIRA Certification Services, UK
|
IECEx SIR 09.0011X
Date:2019-06-06
|
IEC 60079-0:2017;
IEC 60079-1:2014
|
|
2
|
FLP enclosure for cable reel rated at 300A, 1100V, type MA001012-0010
|
JOY
|
Eurofins E&E CML Limited
United Kingdom
|
IECEx CML 23.0084X
Date:2023-08-01
|
IEC 60079-0:2017
IEC 60079-1:2014
|
|
3
|
Connection Box, 5100019785, 1100V
|
JOY
|
Ex Testing & Certification Pty. Ltd., AUS
|
IECEx ITA 15.0016
Date:2019-03-08
|
IEC 60079-0:2017;
IEC 60079-1:2014-06
|
|
4
|
Connection/Switch Box, Type 5100002582, 240V, 50A, Emergency Stop
|
JOY
|
Ex Testing & Certification Pty. Ltd., AUS
|
IECEx ITA 10.0002X
Date:2023-05-30
|
IEC 60079-0:2017
IEC 60079-1:2014-06
|
|
5
|
FLP enclosure, 5100035085, rated at 1500V, 400 A
Main controller
|
JOY
|
Ex Testing & Certification Pty. Ltd., AUS
|
IECEx EXTC 18.0018X
Date:2018-12-19
|
IEC 60079-0:2017;
IEC 60079-1:2014
|
|
6
|
FLP/WP LED mining Luminaire, type ML100,
12-24V AC/DC
drill and headlight
|
Victor
|
Intertek Testing & Certification Ltd, UK
|
IECEx ITS 08.0012
Date:2022-05-10
|
IEC 60079-0:2017
IEC 60079-1:2014
|
|
7
|
FLP/WP fluorescent Luminaire, model ML102, 120V, 15W
Area light
|
Victor
|
SIRA Certification Services, UK
|
SIRA09ATEX1328
Date: Sept-2021
|
EN IEC 60079-0:2018
IEC 60079-1:2014
|
|
8
|
STX-3261 Methane SENSOR
|
Trolex Ltd.
|
ERTL, Kolkata
|
ERTL(E)/TES/T238/0003/01-22/NABL
Date:2022-02-21
|
IEC 60079-0:2017;
IEC 60079-11:2011
|
|
9
|
IS Power supply, BBU TX6648 with interface relay TX6661, 7.5V/12V
|
Trolex Ltd.
|
Eurofins E&E CML Limited, UK
|
IECEx CML 21.0048X
Date:2021-07-06
|
IEC 60079-0:2017
IEC 60079-11:2011
|
|
10
|
TX9042 Programmable Sensor Controller, 12V DC
|
Trolex Ltd.
|
SGS Baseefa Limited, UK
|
IECEx BAS 15.0065X
Date:2023-09-07
|
IEC 60079-0:2017
IEC 60079-11:2023
|
|
11
|
Isolating Switch Amplifier, Type IM1-451-Ex-R
|
Turck
|
TÜV NORD CERT GmbH, Germany
|
IECEx TUN 06.0007X
Date:2022-04-20
|
IEC 60079-0:2017
IEC 60079-11:2011
|
|
12
|
FLP enclosure, 5100016553, rated at 120V rms
for BBU and relay
|
JOY
|
Eurofins E&E CML Limited United Kingdom
|
IECEx CML 18.0112X,
Date:2026-01-20
|
IS/IEC 60079-0:2017;
IEC 60079-1:2014;
|
|