S No. |
Description |
Manufacturer |
TestingLaboratory |
Test Report No |
Standards |
1 |
Cutter Motor, 3 Phase,AC Induction motor,frame 20DB400J, ratedat 210KW, 1050/1140V, 50 HZ, 4 pole, 1465RPM, water cooled. |
BALDOR (ABB) |
SIRACertificationServices, UK |
IECEx SIR 10.0084X
2022-09-01 |
IEC 60079-0:2017
IEC 60079-1:2014 |
2 |
Pump Motor, 3 Phase,AC Induction motor,frame 9CB350J, ratedat 55KW, 1050/1140V,50 HZ, 4 pole,1455/1465 RPM |
BALDOR (ABB) |
SIRACertificationServices, UK |
IECEx SIR 10.0124X
2019-04-10 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
3 |
Gathering Head Motor,3 Phase, AC Inductionmotor, frame 8CA350J,rated at 45KW,1050/1140V, 50 HZ, 4pole, 1365/1370 RPM |
BALDOR (ABB) |
SIRACertificationServices, UK |
IECEx SIR 10.0124X
2019-04-10 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
4 |
Traction motor, 3Phase, AC Inductionmotor, frame10EB280J, rated at60KW, 950V, 4 pole,2210 RPM |
BALDOR (ABB) |
SIRACertificationServices, UK |
IECEx SIR 10.0128X
2021-08-18 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
5 |
Fan motor, 3 Phase,AC Induction motor,frame X0326TCZ,rated at 26KW,1050/1140V, 50 HZ, 4pole, 2945/2960 RPM |
BALDOR (ABB) |
SIRACertificationServices, UK |
IECEX SIR 13.0022X
2019-12-12 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
6 |
FLP/WP A40 rangerestrained ofconnectors (Plug,Socket, plug coupler)rated upto 350A,1300V |
Victor |
CIMFR,Dhanbad |
Baseefa02ATEX0099U
Baseefa02ATEX0098U
20-12-2021 |
EN IEC 60079-0:2018;
EN 60079-1:2014 |
7 |
Connection Box(Trailing Cable), TypeMA001032-0005, ratedat 1100V, 300A |
Joy |
Certification management Limited, UK |
IECEx CML 16.0003X
2019-03-04 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
9 |
Display Unit, type jna2/dp/1.bat |
Joy |
Certification management Limited, UK |
CML 19ATEX2438X
2019-11-15 |
EN IEC 60079-0:2018;
EN 60079-11:2012 |
11 |
Lens Assembly, type5000010113 |
Joy |
TetSafe, Australia |
IECEX TSA 12.0005U
2020-10-28 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
12 |
Switch/ConnectionBox, 5000016252,max. rating 1250V,10A (Start/Stop) |
Joy |
Eurofins E&E CML Limited, UK |
IECEx CML 16.0002
2023-10-31 |
IEC 60079-0:2017
IEC 60079-1:2014 |
13 |
Switch/ConnectionBox, 5100002582,max. rating 240V,50A (E-Stop) |
Joy |
Ex testing and certification,Australia |
IECEx ITA 10.0002X
2023-05-30 |
IEC 60079-0:2017;
IEC 60079-18:2014 |
14 |
FLP Enclosure, Type 5100016553, 120VRMS (Earth leakage) |
Joy |
Certification management Limited, UK |
IECEx CML 18.0112X
2021-03-17 |
IEC 60079-0:2017;
IEC 60079-1:2014;
IEC 60079-11:2011 |
15 |
Siren, Type HSHC,rated at 250V |
Hytronic |
Mining and surface certification, South Africa |
IECEx ICS 17.0003X
2023-10-25 |
IEC 60079-0:2017;
IEC 60079-1:2014;
IEC 60079-11:2023 |
16 |
Sensor enclosure typeMA001042 – 0009, Inclinometer. |
Joy |
Eurofins, UK |
CML 16ATEX1027X
2023-11-22 |
EN IEC 60079-0:2018;
EN 60079-1:2014 |
17 |
LED MiningLuminaire, ML100,12/24V |
Victor |
Intertek Testing & Certification Ltd, UK |
IECEx ITS 08.0012
2022-05-10 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
18 |
Ruggedised Mouseassembly type 5100020129, 5V, 1A |
Joy |
Certification management Limited, UK |
CML 14ATEX1092
2024-01-24 |
EN IEC 60079-0:2018;
EN 60079-1:2014 |
20 |
Multi pin Connector,5000012722, 120V |
Joy |
Ex Testing & Certification Pty. Ltd., Australia |
IECEx ITA 07.0001X
2023-07-19 |
IEC 60079-0:2017
IEC 60079-1:2014 |
21 |
IS Power supply,BBU TX6648,7.5V/12V (Insidemain Controller) |
Trolex Ltd. |
Eurofins E&E CML Limited, UK |
IECEx CML 21.0048X
06-07-2021 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
22 |
Interface RelayTX6661, 8.5V/13V,housed inside main Controller |
Trolex Ltd. |
Housed inside main Controller FLP Enclosure 5000034094- Drawing number- 5000034094-02 |
23 |
TX9042Programmable SensorController, 12VDCsupply |
Trolex Ltd. |
SGS Baseefa Limited, UK |
IECEx BAS 15.0065X
07-09-2023 |
IEC 60079-0:2017;
IEC 60079-11:2023 |
24 |
Methane Sensor,STX3261 |
Trolex Ltd. |
ERTL, Kolkata |
ERTL€/TEST/T238/0003/01-22/NABL
2022-02-21 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
25 |
Audio Visual Alarm(AVA), TX6831 |
Trolex Ltd. |
CSA Group Netherlands |
Sira 99ATEX2152X
2022-04-14 |
EN IEC 60079-0:2018;
EN 60079-11:2012 |
26 |
RS485CommunicationIsolator, 14.4V |
Joy |
TetSafe, Australia |
IECEX TSA 05.0029X
2021-11-17 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
27 |
MBS ISC Remote Pack-M |
Joy |
Ex Testing and certification, Australia |
IECEx ExTC 20.0016X
Dated: 2022-01-31 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
28 |
Receiver, RX1,9.6VDC, 3.1 A |
Joy |
Ex Testing and certification, Australia |
IECEx ExTC 20.0015X
Dated: 02.09.2020 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
29 |
Transmitter-TX2,458.525 MHz |
Joy |
Ex Testing and certification, Australia |
IECEx ExTC 20.0014X
Dated: 02.09.2020 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
30 |
GIO controller,Supply 12V DC |
Joy |
SIRA, UK |
IECEX SIR 06.0046X
2019-03-13 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
31 |
SENSOR,FLOW,PRESSURE AND TEMP, MEASURING GAUGE |
GRUNEWALD GmbH |
DEKRA Testing and Certification, Germany |
IECEx BVS 09.0056X
2023-02-22 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
32 |
PRESSURETransducer, Type 5000045972, I/P110VAC |
Joy |
CSA, Netherlands |
Sira 10ATEX2069
20-04-2018 |
EN IEC 60079-0:2018;
EN 60079-11:2012 |
33 |
Power Supply GIO,I/P supply 120VAC,O/P current 1.8A,type- ISSX1 |
K&H |
TestSafe, Australia |
IECEx TSA 11.0002X
2022-12-08 |
IEC 60079-0:2017;
IEC 60079-11:2011 |
34 |
Solenoid Valve,5000013525, Rated at126VDC, 16.9W |
Joy |
Ex Testing and Certification Pty. Ltd., Australia |
IECEx TRA 16.0009X
03-08-2023 |
IEC 60079-0:2017;
IEC 60079-1:2014 |
35 |
Solenoid Valve enclosure, type 5000012582, 24VDC |
Joy |
Certification Management Limited, UK |
IECx TSA 07.0048X
03-05-2018 |
IEC 60079-0:2017;
IEC 60079-18:2014 |